Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Dental press j. orthod. (Impr.) ; 23(5): 39.e1-39.e13, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-975019

ABSTRACT

Abstract Introduction: The selection of appropriate sites for miniscrew insertion is critical for clinical success. Objectives: The aim of the present study was to evaluate how interradicular spaces measured on panoramic radiograph compare with Cone-Beam Computed Tomography (CBCT), and how crowding can influence the presence of available space for miniscrew insertion, in order to define a new "safe zones" map. Methods: A total of 80 pre-treatment panoramic radiographs and 80 CBCT scans with corresponding digital models were selected from the archives of the department of Dentistry, Aarhus University. Crowding was measured on digital models, while interradicular spaces mesial to the second molars were measured on panoramic radiographs and CBCTs. For panoramic radiographs, a magnification factor was calculated using tooth widths measured on digital models. Statistical analyses were performed to investigate the correlation between the amount of crowding and the available interradicular space. Visual maps showing the amount of interradicular spaces measured were drawn. Results: The most convenient interradicular spaces are those between the second molar and the first premolar in the mandible, and between the central incisors in the maxilla. However, some spaces were revealed to be influenced by crowding. Conclusions: Calibration of panoramic radiographs is of utmost importance. Generally, panoramic radiographs underestimate the available space. Preliminary assessment of miniscrew insertion feasibility and the related selection of required radiographs can be facilitated using the new "safe zone" maps presented in this article.


Resumo Introdução: a seleção de locais apropriados para a inserção de mini-implantes é crítica para o sucesso clínico. Objetivo: os objetivos do presente estudo foram avaliar as medições de espaços inter-radiculares feitas em radiografias panorâmicas e compará-las com as medições feitas com tomografia computadorizada de feixe cônico (TCFC), além de avaliar como o apinhamento pode influenciar na disponibilidade de espaços para inserção dos mini-implantes, no intuito de definir um novo mapa de "áreas seguras". Métodos: foram selecionadas, nos arquivos do departamento de Ortodontia da Aarhus University, 80 radiografias panorâmicas pré-tratamento e 80 imagens de TCFC com os modelos digitais correspondentes. O apinhamento foi medido nos modelos digitais, enquanto os espaços inter-radiculares mesiais aos segundos molares foram medidos nas radiografias panorâmicas e na TCFC. O fator de magnificação das radiografias panorâmicas foi calculado utilizando-se as larguras dentárias medidas nos modelos digitais. Análises estatísticas foram realizadas para investigar a correlação entre a quantidade de apinhamento e o espaço inter-radicular disponível. Foram desenhados mapas visuais mostrando a quantidade dos espaços inter-radiculares medidos. Resultados: os espaços inter-radiculares mais adequados são aqueles entre o segundo molar e o primeiro pré-molar inferior, e entre os incisivos centrais superiores. Porém, verificou-se que alguns espaços são influenciados pelo apinhamento. Conclusões: A calibração das radiografias panorâmicas é de suma importância, pois, geralmente, as radiografias panorâmicas subestimam o espaço disponível. A avaliação preliminar da viabilidade de inserção dos mini-implantes e a seleção das radiografias necessárias para isso podem ser facilitadas utilizando-se os novos mapas de "áreas seguras" aqui apresentados.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Bone Screws , Dental Arch/diagnostic imaging , Orthodontic Anchorage Procedures/methods , Molar/diagnostic imaging , Calibration , Radiography, Panoramic , Retrospective Studies , Dental Arch/anatomy & histology , Dental Implantation/methods , Cone-Beam Computed Tomography , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Molar/anatomy & histology
2.
Int. j. morphol ; 33(4): 1386-1392, Dec. 2015. ilus
Article in English | LILACS | ID: lil-772327

ABSTRACT

The abundant vascular structures that surround the shoulder joint are complex and variable, complicating arthroscopy approaches. The aim of this study is to determine safe and risky areas around standard posterior and standard anterior portals, and accounting for the distribution of neurovascular structures of small and medium diameters that can lead to intra-articular bleeding during surgery. The standard posterior portal, and standard anterior portal were placed as described in the literature, and punch dissection was performed 2.5 cm around the trocar in situ. The arrangement of each identified structure was photographically documented and digitalized for each anatomic plane; the distance to the trocar and the diameter of each structure were measured. Based on each digitalized anatomic plane, safe and risky tissue areas were determined, and a clock face coordinate system was used to represent these areas. The safe area around the standard posterior portal was located between 11 and 1 o´clock for the left shoulder and 11 and 2 o´clock for the right shoulder. For the standard anterior portal, the safe area was located between 2 and 3 o´clock for the left shoulder and between 9 and 12 o´clock for the right shoulder. However, we did document a risk of injuring the cephalic vein 5 times, the axillary artery 3 times and the deltoid branch of the thoracoacromial artery once. This study reports quantitatively the total number of small diameter structures present in the two shoulder arthroscopic portals evaluated. The safe areas proposed in this study must be evaluated to propose new access points for performing arthroscopic procedures on the shoulder.


Las abundantes estructuras vasculares que rodean la articulación del hombro son complejas y variables, y dificultan los abordajes artroscópicos. El objetivo del estudio fue determinar áreas seguras y en riesgo en relación al portal posterior estándar y el portal anterior estándar y cuantificar la distribución de estructuras de diámetro pequeño e intermedio que puedan conducir a sangrado intraarticular durante la cirugía. El portal posterior estándar y el portal anterior estándar fueron colocados según su descripción en la literatura y fueron realizadas disecciones en sacabocado de 2,5 cm alrededor del trocar in situ. La disposición de cada estructura identificada fue documentada fotográficamente y digitalizada para cada plano anatómico. La distancia hacia el trocar y el diámetro de cada estructura fueron medidos. Basado en cada plano anatómico digitalizado, áreas de seguridad y riesgo tisular fueron determinadas y un sistema de coordenadas de manecillas de reloj fue utilizado para representar estas áreas. El área segura alrededor del portal posterior estándar fue localizada entre las 11 y las 1 en el sistema de las manecillas del reloj para hombros izquierdos y entre las 11 y las 2 para hombros derechos. Para el portal anterior estándar, el área segura fue localizada entre las 2 y 3 horas para hombros izquierdos y entre las 9 y 12 horas para hombros derechos. Aun así, se documentó el riesgo de lesionar la vena cefálica en 5 ocasiones, la arteria axilar en 3 ocasiones y la rama deltoidea de la arteria toracroacromial en una ocasión. Este estudio reporta cuantitativamente el número total de estructuras de pequeño diámetro presentes en los dos portales artroscopicos evaluados. Las áreas seguras propuestas en este estudio deben ser evaluadas para proponer nuevos puntos de acceso para la realización de procedimientos artroscopicos en el hombro.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Arthroscopy/methods , Shoulder/anatomy & histology , Cadaver , Cross-Sectional Studies , Patient Positioning
SELECTION OF CITATIONS
SEARCH DETAIL